SAGEM-LINK F 288055571-04
Installation and Operation Manual
Page 55/142
Issue 04 : July 2005
Reproduction and communication prohibited without the written permission of Sagem Communication
Main Pilot Screen for a 1+1 Configuration
Note : Depending on the previous configuration, some alarms may still be present (Trib or Custom).
3.2.4 - Completing Link Configuration
Once the link has been established with the right main parameters, it is necessary to complete the
installation. The remaining parameters to adjust are :
Local and remote tributaries configuration (alarms, impedance)
Site names
BER counting period
Setting Alarm thresholds (BER, RSL)
Alarm relays configuration
Auxiliary channels configuration
Automatic Transmit Power Control (ATPC)
Network Management Interface Parameters (if available)
3.2.4.1 - Tributary Configuration
Click on the button
(top left (local) or top right (remote) of the toolbar on main screen) or use
the menu "Tools / Tributaries / Local or Remote" to open tributary configuration window.
This screen may vary depending on the current capacity. Below is an example for 16xE1 capacity.