SAGEM-LINK F 288055571-04
Installation and Operation Manual
Page 56/142
Issue 04 : July 2005
Reproduction and communication prohibited without the written permission of Sagem Communication
When this button is "ON", an AIS signal
is transmitted when BER > BER
Threshold Alarm
I : the access is not currently used (Invert)
N : The tributary is used (Normal)
active (normal)
S
: AIS emission
BAL 120 : The DB25 Connector
Corresponding to this group
of 4 tributaries is in Balanced
120 Ohm configuration
Unbal 75 : The DB25 Connector
Corresponding to this group of 4
tributaries is in
Unbalanced 75 Ohm configuration
Blank : No Loopback
L : Local trib loopback
R : Remote trib Loopback
Change the different settings by clicking on the corresponding button.
• AIS on BER : when selected, an AIS is sent to the tributary output in case of a BER greater
than 10
-3
.
• Data Alarm :
• if the tributary is not currently used for traffic, then it is necessary to configure it as inverted
(I). In this mode, there will be no tributary alarm for this particular tributary if it is not
connected. However, if this tributary is connected while being in "I" position, a tributary
alarm is generated.
• If the tributary is used for traffic, it is necessary to configure it as normal "N". In this mode
there is an alarm in case of lack of signal at tributary input.
• Service : for normal service select "A" (active). If you select "S", an AIS is returned to the
receive tributary on the local terminal (this AIS is not being transmitted on the remote terminal).
• Loopback : when clicking on a button located on the loopback line, the following screen
appears :