SAGEM-LINK F 288055571-04
Installation and Operation Manual
Page 70/142
Issue 04 : July 2005
Reproduction and communication prohibited without the written permission of Sagem Communication
Cable Interface (modem) Alarms
Demodulation : This alarm is generated if there is a demodulator fault or if received data is not
recovered.
Modulation : This alarm is generated if there is modulator fault. When a modulation alarm
occurs, the transmitter is muted.
NMI (Network Management Interface) Alarms
Eth : This alarm is generated in case of a hardware failure regarding NMI Ethernet interface
ICC : This alarm is generated if there is a communication problem between the Network
management agent and the IDU microprocessor.
MGMT1 : This alarm is generated in case of a communication problem on MGMT1 serial port.
MGMT2 : This alarm is generated in case of a communication problem on MGMT2 serial port.
TSL2 : This alarm is generated in case of a communication problem between the two IDUs of
the link (when the link is broken for instance).