Polarization setting :
- Coupler : ODUs are mounted vertically on the coupler. Depending on the coupler type the
arrow on the ODU cover must be horizontal (Filtel) or vertical (Andrew).
- The polarization can be adjusted from turning the coupler polarizer from 90 degrees
(Andrew) or by replacing polarizer (Filtel). Refer to coupler supplier instructions.
- Antenna : If the antenna has a rectangular waveguide interface, rotate antenna source to
have the wanted polarization. Make sure that polarizations are the same for the antenna
and for the coupler.
Vertical Polarization Horizontal Polarization
Figure 1.6 – Setting the Polarization for Andrew Coupler
Vertical Polarization Horizontal Polarization
Figure 1.7 – Setting the Polarization for Filtel Coupler
1+1 Configuration with a Coupler Remote Mounted and a Standard Antenna :
The coupler is attached on the remote mount and connected to the standard antenna by a flex
guide.
The two ODUs are vertically mounted on the coupler, with the arrows in vertical (Andrew) or
horizontal position (Filtel). Each ODU is connected to the IDU with a coaxial cable.