SAGEM-LINK F 288055571-04
Installation and Operation Manual
Page 27/142
Issue 04 : July 2005
Reproduction and communication prohibited without the written permission of Sagem Communication
Pin Signal 120 Ohm balanced 75 Ohm unbalanced
1 GND Ground Ground
14 TXHDB3P1 Transmit trib #1 - P Transmit trib #1
2 GND Ground Ground
15 TXHDB3N1 Transmit trib #1 - N
Grounded by the cable
3 RXHDB3P1 Receive trib #1 - P Receive trib #1
16 GND Ground Ground
4 RXHDB3N1 Receive trib #1 - N
Grounded by the cable
17 TXHDB3P2 Transmit trib #2 - P Transmit trib #2
5 GND Ground Ground
18 TXHDB3N2 Transmit trib #2 - N
Grounded by the cable
6 RXHDB3P2 Receive trib #2 - P Receive trib #2
19 GND Ground Ground
7 RXHDB3N2 Receive trib #2 - N
Grounded by the cable
20 TXHDB3P3 Transmit trib #3 - P Transmit trib #3
8 GND Ground Ground
21 TXHDB3N3 Transmit trib #3 - N
Grounded by the cable
9 RXHDB3P3 Receive trib #3 - P Receive trib #3
22 GND Ground Ground
10 RXHDB3N3 Receive trib #3 - N
Grounded by the cable
23 TXHDB3P4 Transmit trib #4 - P Transmit trib #4
11 GND Ground Ground
24 TXHDB3N4 Transmit trib #4 - N
Grounded by the cable
12 RXHDB3P4 Receive trib #4 - P Receive trib #4
25 GND Ground Ground
13 RXHDB3N4 Receive trib #4 - N
Grounded by the cable
Figure 1.20 – DB25 Tributary Connector Pinout
1
25
14
13