SAGEM-LINK F 288055571-04
Installation and Operation Manual
Page 51/142
Issue 04 : July 2005
Reproduction and communication prohibited without the written permission of Sagem Communication
The first link configuration is made separately at each end of the link. If the link has been previously
established, then it is possible to configure dynamically parameters only from one side of the link.
The first essential parameters to configure before establishing the link are :
Channel Transmit Frequency
Modulation and Capacity
Transmit Power (ATPC should be in "OFF" position at this time)
Link ID Code
Note : When powering up terminal for the first time, transmitter should be in "MUTE" position, in order
to avoid any interference with other radios while configuring the equipments.
It is necessary to keep transmitter in mute position until transmit frequency, modulation and capacity
are properly configured.
When the link is not established, the main Pilot screen indicates "No remote radio" on the right side of
the screen. An example of a typical screen is given below :
View Only mode
Click here for login
Local terminal parameters are on the left part of the screen, while remote terminal parameters are
located on the right side.
On the top of the screen, current capacity and modulation are displayed. Below are terminal
configuration and Link ID code.
On the middle part of the screen BER indication, Receive Signal Level (RSL), Transmit frequency,
Transmit Power, and ATPC status are indicated.
On the bottom of the screen, main alarms are displayed.