3.2.4.9 - Configuring the 1+1 Operation
Static Phase Adjust
(Space or Frequency Diversity only)
Systems working in space diversity, or frequency diversity, may require a static phase adjust, in order
to compensate the static delay due to the path difference. For hot stand by systems using the same
antenna, this adjustment is not required.
To make a static phase adjust, select the menu : Tools/Diagnostic Tools/Equipment Configuration,
and the following windows appears :
Click on the static phase adjust button to initiate static phase adjustment on the terminal.
Revertive Automatic Switching
When this option is selected, the transmitter and the receiver in traffic are those from the main ODU. If
there is a fault on the main ODU (or on the main cable interface), then the switch select automatically
the standby transmitter or receiver. When the fault is cleared, there is an automatic return to the main
ODU.
This feature is useful when using an asymmetrical coupler for ODU coupling.
When this option is not selected, transmit switch and receive switch position stay on the current
position until a fault appears on the transmitter or on the receiver.
Note that transmit and receive switches are independent.