EasyManua.ls Logo

Sagem SAGEM-LINK F - Page 76

Sagem SAGEM-LINK F
142 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SAGEM-LINK F 288055571-04
Installation and Operation Manual
Page 76/142
Issue 04 : July 2005
Reproduction and communication prohibited without the written permission of Sagem Communication
A Zoom in / Zoom out function is available with the mouse : to enlarge a specific area click on the
Zoom in button
and select an area with the mouse left button.
To return to the previous display, click on the Zoom Out button
.
If you click on the sort list, the following menu appears :
Local transmitter and Remote receiver first
Remote transmitter and Local receiver first
Local equipment and Remote equipment
Each event is displayed for Local then for
Remote equipment
This menu allows the user to sort the list of the events in 4 different ways.
Log files can be saved on the hard disk by clicking on the save button
, or opened by clicking on
the open button
.
Log files can also be saved as text files by clicking on the text button
.
The list of events that may be displayed is as follows. The prefix L or R before the event name means
Local or Remote.
The suffix 1 or 2 means Main or Standby terminal (1+1 systems).
Event Name Event Description
Com Fail
Pilot and local equipment do not communicate
Rem Out
Link broken
Tx Pwr
Transmit Power Alarm
Tx Freq
Transmit Frequency Alarm
Rx Freq
Receive Frequency Alarm
Rx Levl
Receive Level Alarm
LinkID
Link ID Alarm
IDU
IDU Alarm
LauxIn i
Dry Loop Input #i (i = 1 to 4)
RauxIn i
Dry Loop Output #i (i = 1 to 4)
BER Wg
BER Warning
BER Al
BER Alarm
Mod
Modulator Alarm
Demod
Demodulator Alarm
Trib n
Tributary n Fault (n = 1 to 16)

Table of Contents