VM1000 Series
‐93‐
Function
code
Description Set range Unit Default
Modifi
-cation
level
F8.22
Jump frequency
validity during
acceleration/decele
ration
0: Invalid
1: Valid
1 0
F8.23
Option as
accumulative
running time
reached
0: operation continue
1: Error code alarm
1 0
F8.24
Acting option as
accumulative
power-on time
reached
0: operation continue
1: Error code alarm
1 0
F8.25
Frequency point for
switchover
between
acceleration time 1
and acceleration
time 2
0.00Hz~Maximum Frequency 0.01Hz 0.00Hz
F8.26
Frequency point for
switchover
between
deceleration time 1
and deceleration
time 2
0.00Hz~Maximum Frequency 0.01Hz 0.00Hz
F8.27
Terminal jogging
priority
0: Disable
1: Enable
1 1
F8.28
Frequency
detection value
(FDT2)
0.00Hz~Maximum Frequency 0.01Hz 50.00Hz
F8.29
Frequency
detection
hysteresis (FDT 2)
0.0%~100.0% (FDT2 Level) 0.10% 5.00%