VM1000 Series
‐95‐
Function
code
Description Set range Unit Default
Modifi
-cation
level
F8.41
Given current
reached detection
width 2
0.0% ~ 300.0% Motor rated
current
0.10% 100.00% ☆
F8.42 Timing operation
0: Disable
1: Enable
1 0 ☆
F8.43 Timing reference
0: F8.44 Timing setting
1: AI1
2: AI2
3: reserved
1 0 ☆
F8.44 Timing setting 0.0Min ~ 6500.0min 0.1min 0.0min ☆
F8.45
AI1 input voltage
lower limit
0.00V~F8.46 0.01V 3.10V ☆
F8.46
AI1 input voltage
upper limit
F8.45~10.00V 0.01V 6.80V ☆
F8.47
inverter Power
module
temperature
reached
0 ~100 ℃℃ 1℃ 75℃ ☆
F8.48
Rapid current
limiting function
0: Disable
1: Enable
1 1 ☆
F9 Group: PID parameters
F9.00
PID reference
source
0: Preset value(F9.01)
1: Analog terminal AVI
2 Analog terminal ACI
3: Communication interface
4: Muli-function digital input
terminals
1 0 ☆
F9.01 PID preset value 0.0%~100.0% 0.10% 50.0% ☆