SAM4s ER-180T Operator's & Programming Manual v1.4 Program Mode Programming 55
Department Programming
Program 500 - Department Status Programming
Use the following steps to set the status for each department.
1. Turn the key lock to the P position.
2. To begin the program, enter 5 0 0 and press the SUBTOTAL key.
0 SUBTOTAL0 5
3. Select the Department or Departments you wish to program in one of the following
ways:
Press a Department key on the keyboard, or
1
To set a group of departments with the same status, press the first department in the
series and then press the last department.
161
4. Refer to the "Department Status Chart" below to determine the values for N1 through
N8. Enter the values you have selected, press the X/TIME key. (You do not need to
enter preceding zeros.)
N3 N2 N1 N4 N5
X/TIME
(
X
)
N6 N7 N8
5. To program additional Departments, repeat from step 3, or press the CASH/TEND
key to finalize the program.
CASH/TEND
(
=
)
Department Status Chart
Address Program Option Value
N1
Department is negative item Yes = 1
No = 0
N2
Department is single item Yes = 1
No = 0
N3
Department is taxable by rate 4? Yes = 1
No = 0
N4
Department is taxable by rate 3? Yes = 1
No = 0
N5
Department is taxable by rate 2? Yes = 1
No = 0
N6
Department is taxable by rate 1? Yes = 1
No = 0
N7
Department is override preset ?
Yes = 1
No = 0
N8
Department is preset?
Yes = 1
No = 0
Note: Default settings are shown in bold type.