INITIALIZING THE SVMi-20E
Perform a proper SVMi-20E system shut down. (Steps for performing a proper shut down are
described in the section Correct System Shutdown.)
Once the SVMi-20E is down and at a C:> DOS prompt, press the RESET button this will reboot
the SVMi-20E. During the reboot process the SVMi-20E will communicate through a series of
IPC messages to the MCP/MP20 to read the MMC data and initialize the SVMi-20E accordingly.
NOTE: After the SVMi-20E restarts you should change the value of MMC 740 so that it
indicates "MBX Download = No." This will prevent the system from creating new mail boxes
and overwriting any future changes you make to the SVMi-20E database in regards to EXT
and MBX Blocks.
TESTING THE HARDWARE
1. Call each SVMi-20E port individually and confirm that SVMi-20E answers.
2. Call the BI-VMS station group (generally 5049) and confirm that SVMi-20E answers.
If steps 1 and 2 above proved to be successful you have completed the installation and
setup of the SVMi-20E hardware.
You are now ready to begin programming the SVMi-20E Voice Mail/Auto Attendant
system parameters. See the SAMSUNG SVMi-20E Programming Manual.
NOTE: See MMC references in the SVMi-20E Programming Overview documentation for other
MMCs that interact with the SVMi-20E.
CORRECT SYSTEM SHUTDOWN
Whenever possible one of the following procedures should be followed when shutting down
the SVMi-20E system and/or prior to shutting down the telephone equipment.
PROCEDURE ONE
1. From any phone on the system log into KMMC Programming.
2. Using MMC 746 change the status of the SVMi-20E from “processing” to “Halt”.
3. The SDN LED on the front of the SVMi-20E will change from RED to Green. Green
means it is safe to power down the switch.
PROCEDURE TWO
From the Main Status Screen (showing activity and port status):
1. Press 'Escape' and enter System Administration password (Default = 0000).
2. Select 'Operating Utilities' .
3. Select 'Exit the SVMi-20E'’.
4. Enter System Administrator's password (Default = 0000).
5. The SDN LED on the front of the SVMi-20E will change from RED to Green. Green
means it is safe to power down the switch.