EasyManua.ls Logo

Samsung RF263 Series - Pantry Sensor Error

Samsung RF263 Series
67 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
- 20/65 -
Error-code : 7 E
Pantry Sensor Error
Block
Disassemble the VEG BOX and Pantry
Inspect the Yellow 2-WIRE CONNECTOR
Measure the Main PBA DC voltage
- Normal : DC 1.2V(100) ~ 4.0V(-13)
- Failure : DC 1.3V ,4V Inspect the bottom WIRE
CONNECTOR
Inspect the Main PBA CN30
No.9(YEL)+
PBA “GND” marked area
and DC voltage measuring
- Normal : DC 1.2V(100)
~ 4.0V(-13)
- Failure : DC 1.3V ,4V
Inspect the same Liner part
CONNECTOR
DC voltage measuring
- Normal : DC 1.2V(100)
~ 4.0V(-13)
- Failure : DC 1.3V ,4V
Main PBA
CN 30