- 22/65 -
Error-code : 13 E
Humidity - Sensor Error
Block
Disassemble the FF-L DOOR UPP COVER
Inspect the CONNECTOR OPEN
Measure Main PBA CN30 No.1+No.3 DC voltage
- Normal : DC 1.0V(10%) ~ 3.8V(90%)
- Failure : DC 1.0V , 4V Inspect the bottom WIRE
CONNECTOR
Inspect the Main PBA CN30
No.1~3+ HUMIDITY Sensor
WIRE OPEN
Inspect Main PBA CN30
No.1(GRY)+No.3 (WHT/BLU)
DC voltage measuring
- Normal : DC 1.0V(10%)
~ 3.8V(90%)
- Failure : DC 1.0V, 4.0V
Main PBA
CN 30
Back to List