Samsung RF263 Series - Tip 5-2. Inspect R room EVAP DEFROST BUILD

Samsung RF263 Series
67 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
- 50/65 -
Step 1
Touch Display ”Energy Saver”+“Alarm” Key at the
same time for 8 sec until “DingDongsound
occur
※ When Error occurs Measure with moving
TIP 5-1.
- When the ERROR does not exist, “25 E”(R
DEFROST ERROR) Check Step2
Step 2 (Bimetal / HEATER OPEN)
Inspect BIMETAL (RED+BLK) Open
Replace the part
- Normal: 0Ω, Failure: OPEN
Measure Heater (BRN+BRN)resistance
Replace Heater
- Normal: 90~115Ω, - Failure : Open & 0
Voltage of forced Heater On HEATER
partWIRE inspection
- Normal:105~125V, Failure: 0V
Main PBA CN70 7(WHT),CN72 3GRY)
+LINER CONNECTOR WIRE OPEN 점검
Tip 5-2. Inspect R room EVAP DEFROST BUILD
※ Do not Off the power and operate Self-diagnosis test for “TIP 5-1”
first.
Must check forced defrost operation after repair defrosting.
Freezing occurs on all of the EVAP
CN 70
CN 72
Inspect
Bimetal
resistance
Inspect
HEATER
resistance