- 4/65 -
Step 1
① Check for “Child Lock” icon
② Check “Ice Type/Water” Key.
- If it is normal Inspect “Tip 1-2”
- If it is abnormal Inspect Step 2
Step 2
① Check PANEL PBA WIRE HARNESS
Pin connection / switching
- Inspection of 1~5Wire
Verify that the wires are in
the correct order in the connector
① Disassemble the HINGE-UPP COVER, check
the WIRE HARNESS Pin connection/switching
connection and verify the correct sequence
- Inspect BLK / BRN / RED / ORG / YEL
Wire
Step 3
① Disassemble Main PBA Cover in the back
Inspect CN50 ①~⑤Wire Pin contacting and
switching
- BLK / BRN / RED / ORG / YEL Verify that
the wires are in
the correct order in the connector
① If there is no problem on all,
- Replace the PANEL PBA
Check Point
Check the “Ice Type/Water” Key selecting operation.
Tip 1-1. Inspect Display “Ice Type / Water” selecting
CN 50