Step 1
Touch Display ”Energy Saver”+“Alarm” Key for 8
sec at the same time until DingDongsound
appear.
※ When Error occur Measure it with
moving to TIP 5-1.
- If there is no ERROR, “24 E”(Freezing
DEFROST ERROR)
Inspect Step2
Step 2 (Bimetal / HEATER OPEN)
Inspect BIMETAL (RED+BLK) Open
Replace the part
- Normal: 0Ω, Failure: OPEN
Measure Heater (BRN+BRN) resistance
Replace Heater
- Normal: 50~72Ω, - Failure : Open & 0
Forced Heater On HEATER part voltage
Inspect WIRE
- Normal:105~125V, Failure: 0V
Inspect Main PBA CN70 No.9(BRN),CN72
No.3GRY)+LINER Part CONNECTOR WIRE
OPEN
Tip 5-3. Inspect F EVAP DEFROST BUILD
※ Operate Self-diagnosis test into “TIP 5-1” without power
off. Must check forced defrost operation after defrosting
repair.
Freezing on all of EVAP
CN 70
CN 72
Inspect BIMETAL
voltage
Inspect HEATER voltage