Step 3 (DEFROST SENSOR)
No freezing on the bottom of EVAP, Top+
DEFROST SENSOR have ice.
Inspection and replace DEFROST SENSOR
open.
Step 4 (DEFROST SENSOR Sensing location
problem)
No freezing on the bottom of EVAP, EVAP top
+DEFROST SENSOR part don’t have
freezing
Move the location of DEFROST SENSOR to
freezing part.
Step 6 (HEATER location problem)
When freezing on EVAP BOTTOM
- Improve DRAIN freezing.
Remove freezing with STEAMER and check
DRAIN HOLE blocking.
(Remove DRAIN freezing and foreign
substance)
DRAIN FIXER should be on CENTER.
Bending the HATER with hand into bottom.
- DRAIN HOLE should be closed.
HEATER can not contact to PLATE.
Step 7 (Total inspection after defrost reparing)
Check the HEATER operation with forced
defrost operation after complete repairing.
Touch “Energy Saver+Fridgefor 8 sec at the
same time and operate Fd with touching
“Fridge” key 4 times after All LED off.
Check the HEATER (Brown-wire) AC
voltage supplies when “beep“ sounds.
Off with same way if there is no problem
EVAP Top + Sensor Freezing
EVAP top freezing
+ No Sensor freezing
Locate
Sensor
MOVE