Step 1
Select Water, then check the water
dispensing when pressing lever.
- When there is no water dispensing Check
Step 2
- When the water is dispensing check TIP 2-
4
Step 2 (Connection problem-Hose kinked)
Inspect connection between external tap and
the product
- Check if it is connected to water supply
- Check if the tap is closed.
Check for kinked Water supply line
Step 3 (Piercing Valve )
Check for water with piercing valve open and
supply hose disconnected.
(Piercing valves are not recommended)
Step 4 (Filter Case problem)
Remove Water Filter and check dispensing.
If water dispenses ,try a new filter. If
water does not dispense with new filter,
replace the Filter Case.
Step 5
Minimum water supply pressure should be
20 PSI.
If pressure is low due to external filter
(reverse osmosis) remove internal filter.