Samsung RF263 Series - Error-code: 81~86 E INVERTER COMP Error

Samsung RF263 Series
67 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
- 38/65 -
Error-code : 81~86 E
INVERTER COMP Error
Check if overload by touching COMP.
- Operate normally after 8 min in the
case of re-operation.
CONNECTOR OPEN / INVERTER PBA problem
When the COMP is not hot
Inspect the COMP WIRE
Inspect the INVERTER PBA CN 04 3-WIRE
- Check U(BLU), V(PRP), W(BLK) OPEN order
Disassemble COMP RELAY COVER and check PIN
- Check U(BLU), V(PRP), W(BLK) OPEN order
COMP Locked problem(84)
When the COMP is hot
COMP problem /
Cycle Shield System problem
Error
Failure reason
81 E
Operation failure
Operate initial reoperation-rest 8min
COMP U.V.W top SHORT
IPM PIN SHORT
INVERTER PBA failure
82 E
INVER PBA
IPM FAULT
83 E
Comp Abnormal
current Detection
Inspect Inverter PBA CN04
(Changed/OPEN)
Inspect COMP WIRE(Changed/OPEN)
84 E
Motor Locked Over
RPM
Inspect COMP LOCKED / CYCLE
COMP LOW rpm
Reoperation initial-rest 7min
INVERTER PBA
85 E
Comp under voltage
86 E
Comp over
voltage
Check power outlet
INVERTER PBA
CN 73
FUSE Check
OPEN CHECK
CN 04