EasyManua.ls Logo

Samsung RF263 Series - Inspect R EVAP Defrost Build

Samsung RF263 Series
67 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
- 62/65 -
Step 1
Touch the Display ”Energy Saver”+“Alarm” Key for
8 sec at the same time until DingDongsound
occur
※ When Error Measure it to move TIP 5-1.
-No ERROR, or “25 E”(R DEFROST ERROR)
Check Step2
Step 2 (Bimetal / HEATER OPEN)
Inspect BIMETAL (RED+BLK) Open
Change the parts
- Normal: 0Ω, Failure: OPEN
Measure Heater (BRN+BRN)resistance
Replace Heater
- Normal : 90~115Ω, - failure : Open & 0
Forced Heater On HEATER part voltage
Inspect WIRE
- Normal:105~125V, Failure: 0V
Inspect Main PBA CN70 No.7(WHT),CN72
No.3GRY)+LINER part CONNECTOR WIRE
OPEN
Tip 9-3. Inspect R EVAP DEFROST BUILD
※ Before power off, operate self-diagnosis test on “TIP 5-1” first.
Must check forced defrost operation after defrost repairing.
Freezing occurs on all EVAP
CN 70
CN 72
Inspect Bimetal
Resistance
Inspect
HEATER
resistance

Table of Contents

Related product manuals