Step 3 (DEFROST SENSOR)
No freezing on the bottom of EVAP +
DEFROST SENSOR is being ice.
Inspect and replace DEFROST SENSOR
open.
Step 4 (DEFROST SENSOR sensing location
problem)
No freezing on the bottom of EVAP, EVAP top
+DEFROST SENSOR part don’t have freezing
Move the location of DEFROST SENSOR to
freezing part.
Step 6 (HEATER location problem)
When freeze only EVAP BOTTOM
- Improve DRAIN freezing.
Check the drain hole blocking with remove
freezing using STEAMER.
(Remove DRAIN freezing and foreign
substance)
DRAIN FIXER should be on CENTER.
Bending the HEATER into Bottom using
hand.
- DRAIN HOLE should be closed.
HEATER can not contact to PLATE.
Step 7 (Total inspection after defrost repairing)
Check the HEATER operation with forced
defrost operation after complete repairing.
Touch “Energy Saver+Fridgefor 8sec at the
same time to off ALL LEDs and touch the
“Fridge” key for 4 times to operate “rd”.
Check HEATER(Brown-wire)AC voltage
supplying after “beep” sound appear.
Off same way if there is no problem.
No EVAP top freezing
+ Sensor freezing
SENSOR
보임
MOVE
EVAP Top+ Sensor freezing

Table of Contents