- 44/65 -
Step 1
① Check the DOOR OPEN ALARM.
- When ALARM sounds Check Step 2
- When ALARM didn’t sound Check Step
4
Step 2
① Inspect DOOR S/W which has R room DOOR-
L UPP
② Check there is L / R 2points MAGNET
③ Assemble TOP TABLE and inspect
inner DOOR S/W 2points assembly
Step 3
① After disassemble the Display, and inspect
Micro LED S/W operation which is on the
back side of lever.
※ Check it is not pushed or damaged
If there is no problem
① Check the wire harness connection after
disassemble HINGE-UPP COVER
- Inspect CONNECTOR No.7(BLU)+15(GRY)
② Inspect Main PBA Connector
- Inspect CN50 No.5(YEL)and No.7(BLU)
Wire
Check Point
Inspect operation of Dispenser Lever & DOOR S/W .
Tip 3-3. Inspect Lever & DOOR S/W
BLU
GRY