EasyManua.ls Logo

Samsung RF263 Series - C-Fan Motor FG Signal Error

Samsung RF263 Series
67 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
- 27/65 -
Error-code : 23 E
C-Fan Motor FG SIGNAL ERROR
Block
Inspect UNIT COMP C-Fan
- Inspect CONNECTOR No.1~3 Pin contact/switching
Inspect Fan Motor FG output : Main PBA CN76 No.9(BLU)+1(GRY) when Fan
rotate
- Normal : DC 2~4V
- Failure : DC 2V Wire Open inspection Replace Fan
CONNECTOR
※ Wire inspection
Inspect Fan Motor
- Inspect CONNECTOR
No.3(WHT) + Main PBA
CN76 No.9(BLU) WIRE OPEN
- Inspect CONNECTOR
No.2(REL) + Main PBA CN76
No.5(S/BLU) WIRE OPEN
- Inspect CONNECTOR
No.1(BLK) + Main PBA CN76
No.1(GRY) WIRE OPEN
Main PBA
Inspect normal condition
after replace it
Measure Main PBA CN76
No.1(GRY)+9(BLU) DC
voltage on CONNECTOR
contact and POWER ON
condition (Fan ON)
Normal: Measure DC 2~4 V
Failure : DC 2V, 4V
CN 76
1: GND(BLK)
2: VCC(RED)
3: F G (YEL)
Back to List