- 66/65 -
Step 1
Inspect R ICE BUCKET disassemble using
- Cool air comes from icemaker to R room
Inspect Less assemble Ice BUCKET
Gasket + ICE BUCKET GAPAdd CLIP
- Overcooling on R room with cooling air
Leakage
Step 2
Inspect R-ROOM SENSOR single failure
Inspect MAIN PBA SENSOR DC voltage
- ④+”GND
- Normal : DC 1.2V(100) ~ 4.0V(-13)
- Failure : DC 1.3V ,4V Replace
SENSOR
Check Point
Inspect COVER DAMPER
Tip 10-1. Inspect R TOO COLD
GAP
GAP
BUCEKT
ICE BUCKET
Non assemble