Step 3 (DEFROST SENSOR)
No freezing on the bottom of EVAP, top+
DEFROST SENSOR are being ice.
Inspect and replace DEFROST SENSOR
open.
Step 4 (DEFROST SENSOR sensing location
problem)
No freezing on bottom of EVAP, EVAP top +
DEFROST SENSOR part don’t have freezing
Move and fix the DEFROST SENSOR
location to freezing part.
Step 6 (HEATER location problem)
When the EVAP BOTTOM freezes only
- Improve DRAIN freezing.
Check the drain hole blocking with remove
freezing using STEAMER.
(Remove DRAIN freezing and foreign
substance)
DRAIN FIXER should be on CENTER.
Bending the HEATER into Bottom using
hand.
- DRAIN HOLE should be closed.
HEATER can not contact to PLATE.
Step 7 (Total inspect after defrost repairing)
Check the HEATER operation with forced
defrost after complete repairing.
Touch “Energy Saver+Fridgefor 8sec at the
same time to off ALL LEDs and touch the
“Fridge” key for 4 times to operate “Fd.
Check the HEATER(Brown-wire) AC voltage
supplying when “beep” sound occur.
Off same way if there is no problem.