EasyManua.ls Logo

Santerno DCREG4.150 - P120: Speed; Voltage Main Input Polarity; P121: Speed; Voltage Main Input Bias; P122: Speed; Voltage Main Input Gain

Santerno DCREG4.150
200 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
15P0059B3 DCREG2
USER MANUAL DCREG4
150/200
7.2.57 P120: SPEED / VOLTAGE MAIN INPUT POLARITY
P120 VrefPol
P
P120 - VrefPol
***
R
0 ... 2
D
0
F
This parameter sets the polarity allowed for REF main reference between
terminals 5 and 7 AFTER applying Gain and Bias operators. This is true only if
this input is a speed / voltage reference, i.e. when the digital input programmed
for the 6:Slave function is open (see par. C130 … C135).
0:Bipolar. Bipolar reference.
1:Positive only. Positive reference only.
2:Negative only. Negative reference only.
If you program a unipolar REF reference, the reference of the opposite polarity
will be shut and considered as equal to zero.
7.2.58 P121: SPEED / VOLTAGE MAIN INPUT BIAS
P121 VrefBias
P
P121 - VrefBias
******%
R
-400.0 ... 400. %
D
0.000 %
F
This parameter represents, as a percentage of the max. value corresponding to
10V, the reference value obtained when the signal applied to the REF main input
between terminals 5 and 7 is equal to zero. Signal V
2
obtained when applying
the Gain and Bias operators to signal V
1
is given by the following formula:
100
121
10
100
122
12
PP
VV
This is true if this signal is a speed / voltage reference, i.e. when the digital input
programmed for the 6:Slave function is open (see par. C130 … C135).
7.2.59 P122: SPEED / VOLTAGE MAIN INPUT GAIN
P122 VrefGain
P
P122 - VrefGain
******%
R
-800.0 ... 800.0 %
D
100.0 %
F
This parameter represents the amplification which is internally applied to the
REF main reference signal between terminals 5 and 7, before being summed to
the Bias. Signal V
2
obtained when applying the Gain and Bias operators to
signal V
1
is given by the following formula:
100
121
10
100
122
12
PP
VV
This is true if this signal is a speed / voltage reference, i.e. when the digital input
programmed for the 6:Slave function is open (see par. C130 … C135).

Table of Contents