15P0059B3 DCREG2
USER MANUAL DCREG4
154/200
7.2.67 P151(154): ANALOG OUTPUT 1(2) BIAS
P151(154) - AnOut1(2)Bias
P151: Bias for analog output 1 on terminal 8.
P154: Bias for analog output 2 on terminal 10.
This parameter indicates, as a percentage of the max. signal corresponding to
10V, the value of the signal generated in the terminal board when the internal
signal is equal to zero. Signal V
2
obtained when applying the Gain and Bias
operators to signal V
1
is given by the following formula:
100
10
100
12
Bias ...PGain ...P
VV
7.2.68 P152(155): ANALOG OUTPUT 1(2) GAIN
P152(155) - AnOut1(2)Gain
P152: Gain for analog output 1 on terminal 8
P155: Gain for analog output 2 on terminal 10
This parameter indicates the amplification that is internally applied to the
generated signal before summing the Bias. Signal V
2
obtained when applying
the Gain and Bias operators to signal V
1
is given by the following formula:
100
10
100
12
Bias ...PGain ...P
VV
7.2.69 P156: ANALOG IOUT POLARITY ON TERMINAL 6
P156 - IOutPol (used in DCREG4 only)
DCREG4: 0
DCREG2: 1(not used)
This parameter defines the range of current analog output I Out on terminal 6. It
is available in DCREG4 only.
0:Bipolar. Bipolar range: the ammeter connected is to be a central-zero one.
1:Positive only. Unipolar range: the ammeter connected is NOT to be a central-
zero one.