C110: Determines command source n.1.
C111: Determines command source n.2.
C112: Determines command source n.3.
0:Disabled. This selection does not enable any command source.
1:Terminal. This selection enables the terminal board as a command source.
2:UpDownRef. This selection enables the internal Up / Down reference as a
command source.
3:Serial Link. This selection enables the serial connection as a command
source.
4:FieldBus. This selection enables the field bus as a command source.
The user may select max. three sources, therefore the MainRef may by equal to
the sum of the references coming from all three available sources. If the same
source is enabled by two or multiple selections, this corresponds to selecting
this source only once.
” and “SAVE” keys, the values of the four parameters change as follows:
C110 2:KeyPad
C111 0:Disabled
C112 0:Disabled
These parameters cannot be changed in LOCAL mode.