32/200
OVERLOAD CAPACITY
Repetitive overload cycle, I = K • I
mot
for 1m and I = I
mot
for 9m @ T = 40°C (room temperature), available after
operating at a motor current (programmable with par. C000) lower than or equal to rated armature current
I
arm nom
for a time long enough thus allowing reaching thermal balance.
SIZE
MODEL
K
(par. P060, P061)
OVERLOAD
PERCENTAGE
Imot
BASE CURRENT
FOR SPECIFIED
OVERLOAD
(A)
Gr.1
DCREG2(4).10
150%
10
DCREG2(4).20
20
DCREG2(4).40
40
DCREG2(4).70
70
DCREG2(4).100
100
DCREG2(4).150
150
DCREG2(4).180
180
DCREG2(4).250
250
DCREG2(4).350
350
Gr.2
DCREG2(4).410
410
DCREG2(4).500
500
DCREG2(4).600
600
DCREG2(4).750
750
DCREG2(4).900
900
Gr.2A
DCREG2(4).900
900
DCREG2(4).1200
1200
MODULAR.S
DCREG2(4).1050
125%
1000
DCREG4.1250
1100
DCREG4.1400
1200
DCREG2(4).1600
1400
DCREG2(4).1800
1640
DCREG2(4).2000
1750
DCREG2(4).2300
2000
DCREG2(4).2500
2200
DCREG2(4).2700
2480
DCREG2(4).3000
2500
DCREG2(4).3500
3000
DCREG2(4).4500
3700
I
ARM
(A)
t
K I
mot
I
arm nom
I
mot
1min
9min