-36-
Group/
Item
Item Name Function Initial Range Note
12 Fan Switch Auto/Max/Min/Manual Switch 0 0-3 0: Auto 1: Max 2:Min 3: Manual
13 Hi-Land Switch Hi-Land Switch 0 0-5
0: Normal Mode , 1: High-land Mode
2˜4: High-land Mode1 ˜ 3, 5: Fixed(13.5V)
14 Safety Switch FAN Control 0 0-4 * Test Purpose
15 Fan1 Manual Voltage
Manual Adjustment Mode at FAN_CON-
TROL_SW=3
130 0-255
16 Fan2 Manual Voltage
Manual Adjustment Mode at FAN_CON-
TROL_SW=3
130 0-255
17
TEM P _UPWARNIN G_TIM E_A
(OUTSIDE)
Raise Temp Failure Value for X minutes
after Power ON
3 0-5
18
TEMP_ U PWARNIN G _ TIME_B
(PANEL)
Raise Temp Failure Value for X minutes
after Power ON
3 0-5
19
TEMP _ UPWA RNING_ T IME_C
(LAMP)
Raise Temp Failure Value for X minutes
after Power ON
3 0-5
20
TEMP_UPWARNING_TIME_B-A
Raise Temp Failure Value for X minutes
after Power ON
3 0-5
21
TEMP_UPWARNING_TIME_C-A
Raise Temp Failure Value for X minutes
after Power ON
3 0-5
22
UPWARNING_TEMP_A (OUT-
SIDE)
Raise Temp Failure Value for a certain
minutes after Power ON
5 0-50
23
UPWARNING_TEMP_B (PANEL)
Raise Temp Failure Value for a certain
minutes after Power ON
5 0-50
24
UPWARNING_TEMP_C (LAMP)
Raise Temp Failure Value for a certain
minutes after Power ON
5 0-50
25
UPWARNING_TEMP_B-A
Raise Temp Failure Value for a certain
minutes after Power ON
5 0-50
26
UPWARNING_TEMP_C-A
Raise Temp Failure Value for a certain
minutes after Power ON
5 0-50
27
FAN_1_START_SPEED FAN1 Start Voltage 8V Unit VX10 55 0-135
28 FAN_2_START_SPEED FAN2 Start Voltage 8V Unit VX10
65 0-135
31 FAN_1_COOLING_SPEED FAN1 Voltage at Power OFF (Fan Mode L1) 100 0-135
32 FAN_2_COOLING_SPEED FAN2 Voltage at Power OFF (Fan Mode L1)
100 0-135
33 FAN_1_TEMPERROR_SPEED FAN1 Voltage at Temp. Failure 130 0-135
34 FAN_2_TEMPERROR_SPEED FAN1 Voltage at Temp. Failure 130 0-135
35 Cooling Time L1
Cooling Time Setting for Fan Mode L1
(x30sec) 1: 30 sec, 3: 90 sec, 15: 450 sec.
3 1-15
36 Cooling Time L2
Cooling Time Setting for Fan Mode L2
(x30sec) 1: 30 sec, 3: 90 sec, 15: 450 sec.
4 1-15
37 IGNORE_TEMP_CHANGE_RATE
Decides Ignore Temp. Failure at the Temp.
rising (X/10) ºC a second
(0.1ºC step, Initial Value 10=1ºC)
10 5-50
38 IGNORE_TEMP_CHANGE_TIMES
Decides Temp Failure when ingore temp
occurs X times
5 1-9
42
HI_TEMP_FAN1_MIN FAN1 Control Start Temperature in High 31 0-255
43 HI_TEMP_FAN1_MAX FAN1 Control End Temperature in High 39 0-255
44 HI_TEMP_FAN2_MIN FAN2 Control Start Temperature in High 31 0-255
45 HI_TEMP_FAN2_MAX FAN2 Control End Temperature in High 39 0-255
46 HI_VALU_FAN1_MIN
FAN1 Control Mini Value in High
(0:Fan Voltage 0V,255: Fan Voltage 25.5V)
65 0-255
47 HI_VALU_FAN1_MAX FAN1 Control Max Value in High 135 0-255
48 HI_VALU_FAN2_MIN FAN2 Control Mini Value In High 75 0-255
49 HI_VALU_FAN2_MAX FAN2 Control Max Value In High 130 0-255
50 NOR_TEMP_FAN1_MIN FAN1 Control Start Tempurature in Normal 31 0-255
51 NOR_TEMP_FAN1_MAX FAN1 Control End Tempurature in Normal 38 0-255
52 NOR_TEMP_FAN2_MIN FAN2 Control Start Temprature in Normal
31 0-255
53 NOR_TEMP_FAN2_MAX FAN2 Control End Tempurature in Normal 38 0-255
54 NOR_VALU_FAN1_MIN FAN1 Control Mini Value in Normal 55 0-255
55 NOR_VALU_FAN1_MAX FAN1 Control Max Value in Normal 125 0-255
56 NOR_VALU_FAN2_MIN FAN2 Control Mini Value In Normal 55 0-255
57 NOR_VALU_FAN2_MAX FAN2 Control Max Value In Normal 115 0-255
58 HIHIGH_TEMP_FAN1_MIN
FAN1 Control Start Temperature in High-
land High
29 0-255
59 HIHIGH_TEMP_FAN1_MAX
FAN1 Control End Temperature in High-
land High
29 0-255
60 HIHIGH_TEMP_FAN2_MIN
FAN2 Control Start Temperature in High-
land High
29 0-255
61 HIHIGH_TEMP_FAN2_MAX
FAN2 Control End Temperature in High-
land High
29 0-255
62
HIHIGH_VALU_FAN1_MIN
FAN1 Control Min Value in High-land
High
135 0-255
63 HIHIGH_VALU_FAN1_MAX
FAN1 Control Max Value in High-land
High
135 0-255
64 HIHIGH_VALU_FAN2_MIN
FAN2 Control Min Value in High-land
High
130 0-255
65 HIHIGH_VALU_FAN2_MAX
FAN2 Control Max Value in High-land
High
130 0-255
66 HINOR_TEMP_FAN1_MIN
FAN1 Control Start Temperature in High-
land Normal
30 0-255
67 HINOR_TEMP_FAN1_MAX
FAN1 Control End Temperature in High-
land Normal
30 0-255
68 HINOR_TEMP_FAN2_MIN
FAN2 Control Start Temperature in High-
land Normal
30 0-255
69 HINOR_TEMP_FAN2_MAX
FAN2 Control End Temperature in High-
land Normal
30 0-255
70 HINOR_VALU_FAN1_MIN
FAN1 Control Min Value in High-land
Normal
125 0-255
71 HINOR_VALU_FAN1_MAX
FAN1 Control Max Value in High-land
Normal
125 0-255
72 HINOR_VALU_FAN2_MIN
FAN2 Control Min Value in High-land
Normal
115 0-255
Electrical Adjustments