-51-
Electrical Adjustment
Grp / No. Item Function Range Initial Note
15 HXT_BDAT1 0 ~ 255 0
16 HXT_BDAT2 0 ~ 255 0
17 HXT_BDAT3 0 ~ 255 0
18 HXT_TH1 0 ~ 255 0
19 HXT_TH2 0 ~ 255 0
20 HXT_TH3 0 ~ 255 0
21 HXT_TH4 0 ~ 255 0
22 SEL_MODE2 0 ~ 7 5
200 Option
0 Logo Display Prohibition 0:Menu 1:Forced 0 - 1 0
1 RS232C Baudrate 0: 19200bps 1: 9600bps 0 - 1 0
4 CABLE SW Long Cable 0: Disable 1: Enable 0 - 1 0
5 PW Debug Command Enable
0: Disable (Sanyo Serial Command Enable)
1: Enable (PW Debug Mode)
0 - 1 0
6 Device Refresh Disable 0: Enable 1: Disable 0 - 1 0
8 PJ-NET Hung up check 0: Enable 1: Disable 0 - 1 0
15 Lens Shift Position Default Setting Reset when the value is set to 10 0 - 10 0
50 Lamp Replacement Display 1:On 0:Off 0 - 1 1
51 Filter Warning Display 1:On 0:Off 0 - 1 1
53 Filter Counter Reset Times Read only 0 - 255 0
54 Factory Default Execute Times Read only 0 - 255 0
55 Motor Operation Stop 0: Enable 1: Disable 0 - 1 0
56 Menu Position Change (X) 0 - 1024 0
57 Menu Position CHange (Y) 0 - 1024 0
58 Lamp Go Out Lamp goes out 0 - 1 0
63 Source Search Enable 0: Disable, 1: Enable 0 - 1 1
64 Input Search Skip Enable 0: Disable, 1: Enable 0 - 1 1
70 ADC Device Select for Analog PC 0 = ISL51002, 1 = PW392 AFE 0 - 1 0
71 ADC Device Select for Component 0 = ISL51002, 1 = PW392 AFE 0 - 1 1
72 Component/RGB Auto switch 0: Disable, 1: Enable if set 1, disable items 70 and 71 0 - 1 0
80 Destination Language Set at Shipping 0:English 1:Japanese 0 - 1 0
95 Flicker Mode 1 0: Disable, 1: Enable 0 - 1 0
96 Flicker Mode 2 0 - 15 8
100 Disable Auto Picture Control 0 : Normal operation 1 : Auto Picture Control Off 0 - 1 0
110 Monitor out at Cooling 0: Output at Cooling time, 0: Disable at Cooling 0 - 1 0
120 HDMI HPD/EDIO 0: Enable, 1: Disable 0 - 1 1
130 Start Logo Counter 0: 30 sec. 1: 20 sec. 0 - 1 0
201 Option (Signal)
0 FrameLock Option
Frame Lock Setting 0:Off at PC , 1: Off at AV, 2: All Off, 3:
Normal, 4: Normal
0 - 4 4
1 Dither Enable 0: Disable 1: Enable 0 - 1 1
3 Field Sense Invert Enable 0: Disable, 1: Enable 0 - 1 0
205 Spread Spectrum
0 0 - 1 1
1 0 - 300 200
2 1 - 500 150
210 Lamp Contol
0 Dimmer SW 0:Auto 1:Manual 0 - 1 0
1 Manual Control
Lamp Power Manual Control (DIMMER_CTRL_LEVEL
0(Dark)~15(Bright))
0 - 15 0
2 DIMMER_CTRL_LEVEL1 Y Level1 Data for Dimmer 0 - 255 7
3 DIMMER_CTRL_LEVEL2 Y Level2 Data for Dimmer 0 - 255 14
4 DIMMER_CTRL_LEVEL3 Y Level3 Data for Dimmer 0 - 255 21
5 DIMMER_CTRL_LEVEL4 Y Level4 Data for Dimmer 0 - 255 28
6 DIMMER_CTRL_LEVEL5 Y Level5 Data for Dimmer 0 - 255 35
7 DIMMER_CTRL_LEVEL6 Y Level6 Data for Dimmer 0 - 255 42
8 DIMMER_CTRL_LEVEL7 Y Level7 Data for Dimmer 0 - 255 49
9 DIMMER_CTRL_LEVEL8 Y Level8 Data for Dimmer 0 - 255 56
10 DIMMER_CTRL_LEVEL9 Y Level9 Data for Dimmer 0 - 255 63
11 DIMMER_CTRL_LEVEL10 Y Level10 Data for Dimmer 0 - 255 70
12 DIMMER_CTRL_LEVEL11 Y Level11 Data for Dimmer 0 - 255 77
13 DIMMER_CTRL_LEVEL12 Y Level12 Data for Dimmer 0 - 255 84
14 DIMMER_CTRL_LEVEL13 Y Level13 Data for Dimmer 0 - 255 91
15 DIMMER_CTRL_LEVEL14 Y Level14 Data for Dimmer 0 - 255 98
16 DIMMER_CTRL_LEVEL15 Y Level15 Data for Dimmer 0 - 255 105
17 DIMMER_AVERAGE_POINT Y Average Point 1 - 16 4
18 DIMMER_AVERAGE_DATA Y Average Data (Read only) - -