Electrical Adjustment
Grp / No. Item Function Range Initial Note
255 (XM100) Fan Start/Cooling Setting
0 Fan1 Initial Volt
Fan Start Voltage (0.1V)
0-255 45
1 Fan2 Initial Volt 0-255 45
2 Fan3 Initial Volt 0-255 70
3 Fan4 Initial Volt 0-255 45
4 Fan5 Initial Volt 0-255 65
5 Fan6 Initial Volt 0-255 70
6 Fan7 Initial Volt 0-255 55
8 Cooling Time Coolong Time Setting (x30 sec.) 1: 30 3: 90 15: 450 1-15 3
10 Temp Error Cooling Time
Cooling Time Setting When the Temp Error occurs (x30 sec.)
1: 30 3: 90 15: 450
1-15 3
11 OnStart Cooling Start Threshold 0-100 38
12 After shutdown cooling Cooling Operation after Shut Down (0: No, 1: Yes) 0-1 1
256 Fan Lamp Voltage Down Setting
0 Lamp Voltage Current Lamp Voltage (0.1V) (Read only) 0-255 ---
1 Lamp Vol Threshold Threshold Voltage (0.1V) 30-90 30
2 Fan1 Speed Gain Fan Speed Ad Gain (0.1V) 0-1500 0
3 Fan2 Speed Gain 0-1500 10
4 Fan3 Speed Gain 0-1500 10
5 Fan4 Speed Gain 0-1500 10
10
257 Fan Setting at Dimmer
0 Dimmer Average Check Period
Dimmer Average Check Period (sec.)
0: 10, 1: 30, 2: 60, 3: 90……10:300
0-10 1
259 Fan Air Pressure Setting
0 Press Source Range Low Pressure Sensor Control Range (AD) 0-1023 661
1 Press Source Range High 0-1023 398
6 Press Fan Add Range High Add value of Fan control for Lamp Fan at Normal 0-5000 10
7 Press Fan Add Range Low 0-5000 30
8 Press Fan Add Range High Add value of Fan control for other fans at Normal 0-5000 20
9 Press Fan Add Range Low 0-5000 40
10 Press Fan Add Range High Add value of Fan control for Lamp Fan at Eco 0-5000 5
11 Press Fan Add Range Low 0-5000 15
12 Press Fan Add Range High Add value of Fan control for other fans at Eco 0-5000 20
13 Press Fan Add Range Low 0-5000 40
17 Temp A Warning Normal Highland Temp A (Room) to judge the Temp Error at Normal/Highland 0 - 100 48
18 Temp B Warning Normal Highland Temp B (Lamp) to judge the Temp Error at Normal/Highland 0 - 100 73
19 Temp CB Warning Normal Hiland Temp C (Panel) to judge the Temp Error at Normal/Highland 0 - 100 67
20 Temp A Warning Eco Highland Temp A (Room) to judge the Temp Error at Eco/Highland 0 - 100 48
21 Temp B Warning Eco Highland Temp B (Lamp) to judge the Temp Error at Eco/Highland 0 - 100 71
22 Temp C Warning Eco Hilghand Temp C (Panel) to judge the Temp Error at Eco/Highland 0 - 100 65
260 Auto Calibration (Common) * Auto calibration
0 Execute Calibration
Execute Calibration when the Value is changed. (For PC White
100%)
0 - 1 0
1 Loop Count Max Times of Calibration 1 - 30 8
2 Auto Status
Calibration Log (Read only)
0: Calibration End Correctly 1: On Adjusting 9: Calibration
Error
0 / 1 / 9 0
3 AutoWait Waiting time 1 - 20 3
4 CHECK - Tolerance Tolerance of Offset 1 - 255 4
5 Time out wait Wait Time until Time out [sec.] 1 - 255 20
261 Auto Calibration (RGB) PW392-AFE MDL <10bits>
0 OFFSET AREA H START Black Level Acq. Area H Start 0 - 1000 975
1 OFFSET AREA V START Black Level Acq. Area V Start 0 - 1000 500
2 GAIN AREA H START White Level Acq. Area H Start 0 - 1000 25
3 GAIN AREA V START White Level Acq. Area V Start 0 - 1000 500
4 Image AREA H WIDTH Black/White Level Area Width 0 - 4095 13
5 Image AREA V HEIGHT Black/White Level Area Height 0 - 4095 9
6 OFFSET Target Black Level Adj target 0 - 1023 20
7 OFFSET Tolerance Black Level Adj telerance 1 - 1023 1
8 GAIN Target White Level Adj target 0 - 1023 955
9 GAIN Tolerance White Level Adj telerance 1 - 1023 1
10 Image Level Tolerance Acq. Image Level Adj Tolerance 1 - 255 8