10
PROCEDURE:
- By pressing MODE key the unit acquires the first weight, on the display is shown “ - - 1 - - -";
- By pressing again MODE key, the unit acquires the second weight, and on the display is shown “- -
2 - - -“.
- NOTE: The acquisition of the second weight is made only if the setting of the rEACt parameter in
the set-up environment has been respected (passage by zero of the weight instability, or always);
see section 9.11 “REENABLING OF THE PRINTOUTS AND THE INDICATOR FUNCTIONS”.
- When the second weight is acquired, the data printout is commanded:
It is possible to interrupt the weighing cycle by pressing the C after the acquisition of the first weight: On
the display the message “ CLEAr ” is shown accompanied by a prolonged beep. Press ENTER to
confirm the cancelling of the first acquired weight or another key to not confirm.
NOTES:
The first weight is acquired if:
- With a NON APPROVED scale one has a STABLE weight and GREATER than 0.
- With an APPROVED scale one has a STABLE weight and GREATER than 20 divisions.
The second weight is acquired if:
- With a NON APPROVED scale one has a STABLE weight and GREATER than 0.
- With an APPROVED scale one has a STABLE weight and GREATER than 20 divisions.
- if the setting of the rEACt parameter in the set-up environment has been respected (passage by
zero of the weight, instability, or always); see section “REENABLING OF THE PRINTOUTS AND
THE INDICATOR FUNCTIONS”.
- the tare operations are DISABLED.
17.5 HORIZONTAL TOTALIZER (Sum of lots -> tot 0)
If the unit is switched OFF, the totalizer will be resetted
Tot.Mod : TYPE OF TOTALISATION (NORMAL, FAST, AUTOMATIC)
Once the totalizer operating mode is selected, both horizontal and vertical, one is asked to set the type
of totalization: normal (t.norM), fast (t.FASt) or automatic (Auto); with ->0<- or ->T<- one changes the
parameter; with ENTER one confirms.
- t.norM : In the normal totalisation, for each accumulation operation there is the display of the weigh
number and the net weight total, before the printing of the data.
- t.FASt : In the fast one, just the display of the "-tot-" message appears on the display, before the
printing of the data.
- Auto : In the automatic one, there is the automatic acquisition of the stable weight; therefore the
display of the "-tot-" message on the display and then the printing of the data.
MAx.tot: NUMBER OF CONSECUTIVE TOTALISATIONS AFTER WHICH THE TOTAL IS
AUTOMATICALLY PRINTED AND RESET
After having carried out the set weighs, the accumulated general total is printed and reset; set a value
between 00 and 63.
NOTE: the value 00 disables the function
TOTALISATION OPERATIONS
In order to carry out the totalisation it is necessary to press the MODE key (if the automatic totalisation
has not been set): the weight is accumulated in two total levels (a partial total and a general total).
To totalize, the net weight must be at least one division with non approved instrument and of at
least 20 divisions with approved instrument.
To avoid undesired accumulations, the "MODE" key is active just once; it reactivates depending on the