12
- "uM.APW" : unit of measure of the average unit weight (APW).
Press ENTER to enter the step.
With the ->0<- or ->T<- keys select the unit of measure (g / kg / t / Lb).
Confirm with ENTER
- "WAit.t" : sampling interval.
Setting of the sampling time (in seconds, with a decimal); greater is the time set and more precise
will the calculated APW be.
Press ENTER to enter the step.
Set the desired time.
Confirm with ENTER
Press many times the C key until the display shows the message “SAVE?”.
Press ENTER to confirm the changes made or another key to not save.
COUNTING PROCEDURE
The operations to be carried out are the following:
1) Place the empty container on the scale and press ->T<- to tare it.
2) Check that the zero is on the display and press the MODE button: the counting function activates
3) The display suggests a REFERENCE QUANTITY. The possible options are: 5, 10, 20, 30, 40, 50,
60, 75, 100, 200.
4) Press “->0<- or ->T<-” the number of times needed to reach the desired sample size.
5) Put the quantity of pieces chosen for the SAMPLE on the scale and press ENTER to confirm or C to
cancel the operation and return to weighing.
6) Press ENTER the display will indicate SAMPL and the indicator will calculate the Average Piece
Weight (APW). After a few instants (time set in parameter Wait.t) the display will indicate the
quantity selected put on the platform.
7) Add the rest of the items to count in the container and whose value will appear on the display.
8) Unload the scale, the APW will remain stored in memory for the next counting of similar pieces,
without having to repeat the REFERENCE operation.
9) By pressing the MODE key one switches from the display of the number of pieces piece (LED
"SPE" on) to the display of the net weight piece (LED "SPE" off) and vice versa.
10) To carry out a new reference operation, press the MODE key and repeat the operations as
describe in point 3).
NOTE: If the number of calculated pieces is greater than 999999, the display shows just the first 6 digits
on the right.
PIECE COUNTING IN EXTRACTION
1) Load a FULL container on the scale and press "->T<-" to tare it.
2) Press "MODE": The display suggests various REFERENCE QUANTITIES:
5,10,20,30,40,50,60,75,100,200
3) Press "->0<- or ->T<- " various times until the chosen quantity is displayed.
4) From the container take off the same number of pieces and press "ENTER/PRINT” to confirm. The
display shows "SAMPL" while the indicator calculates the Average Piece Weight. The display shows
in negative the quantity extracted.
5) Continue the counting in extraction.
“Er.Mot” ERROR DUE TO WEIGHT INSTABILITY DURING THE SAMPLING
It may happen that during the sampling phase the weight is unstable and therefore it is not possible to
correctly calculate the APW. The “Er.Mot” is shown remaining for about three seconds. One should
therefore repeat the sampling operation.