Rewriting number: number of 5 digits which may go from 00000 to 00255; it indicates the number of
complete rewritings of the alibi memory.
Weigh number: number of 6 digits which may go from 00000 to 131072; it indicates the weigh number
in the current rewriting of the alibi memory
With each storage the weigh number is increased of 000001; when this reaches the 131072 value, it
restarts from 000000 and the rewriting number increases of 00001.
Example:
If the stored weigh is the following:
“PIDST,1, 1.000kg, 1.000kg,00126-131072”
and the following will be:
“PIDST,1, 1.000kg, 1.000kg,00127-000000”
The storage of a weigh is possible only if the weight is stable, valid (in other words not in underload nor
in overload) and if the gross weight is equal or greater than zero. If these conditions are not respected:
- in the response to the PID serial command one has "NO" in the place of the ID.
- there is no transmission if ENTER has been pressed.
When the weight is transmitted with the ID following the pressing of the ENTER key, the display shows
for about 2 seconds the message " tr.id ", and the transmitted string is the following:
<ESC>[II]PIDSS,B,LLLLLLLLLLUU,YYTTTTTTTTTTUU,(ID | NO)<STX>.
See the following section “Serial commands” for the string description.
NOTES:
- With approved instrument, the storage of the weigh and the following transmission of the ID to PC
by pressing a key is possible only if the printout is active (or passage from 0 or weight instability and
minimum weight of 20 divisions).
- With approved or not approved instrument, the storage of the weigh through the PID serial
command is always possible for all the weighs from 0 to full range value.
READING OF THE WEIGHS CARRIED OUT
In order to read the information relative to the weighs carried out:
- Press the MODE key.
- The message "rew.id" appears; now one should enter the rewriting number (from 00000 to 00255)
and press ENTER
- The message “ id “ appears; now one should enter the weigh number (from 000000 to 131072) and
press ENTER
- Now it is possible to view on the display the weigh information in sequence, and scroll through it
with the ->0<- key (ahead) or the ->T<- key (backwards):
"ch. x", in which x is the scale number (always 1).
" um yy" in which yy is the unit of measure (kg, g, t o lb).
gross weight (for about a second the message "GroSS" appears and then the gross weight
value).
Tare weight (for about a second the message "tArE" appears or "tArEpt" if it is a manual tare;
then the tare value appears).
- Press C to return to weighing.
NOTES:
- The alibi memory can store up to 131072 weighs; then the rewriting takes place from the beginning.