30 Schaeer Technologies
About the heating modes
Temperature mode
Heating of workpieces to a set temperature; the temperature
of the workpiece is monitored during the whole process. In the
settings menu, it is possible to select a double measurement
/ ΔT measurement here. T1 (temperature sensor 1) is the main
sensor here and is the master for the heating process.
In this mode, one or more temperature sensors have to be
used that are positioned on the workpiece to be heated.
Time mode
Heating of workpieces over time. The heating process is
performed for a set time. The workpiece temperature is not
measured or checked.
This mode can be used when you know in advance how long it
takes to heat a given workpiece to a given temperature.
This is the only mode in which the heater can function without
temperature sensors being connected.
Time or Temperature mode
Heating of workpieces to a set temperature with the
temperature of the workpiece being monitored during the
whole process, or heating over time.
In the settings menu, it is possible to select a double
measurement / ΔT measurement here. T1 (temperature
sensor 1) is the main sensor here and is the master for the
heating process. In this mode, both the desired workpiece
temperature and the desired heating time have to be set. The
heater switches o when one of the two settings (temperature
or time) is reached or has elapsed.
In this mode, one or more temperature sensors have to be
used that are positioned on the workpiece to be heated.
If required, press “Default” to call up the default settings
of the heater as set in the settings menu.