EasyManua.ls Logo

Schaeffler SMART Series - Page 31

Schaeffler SMART Series
64 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Schaeer Technologies
31
Temperature and speed mode
Heating of workpieces to a set temperature; the temperature
of the workpiece is monitored during the whole process.
In this mode, a gradient is also entered with which the heating
process may take place. In the settings menu, it is possible
to select a double measurement / ΔT measurement here. T1
(temperature sensor 1) is the main sensor here and is the
master for the heating process.
For example: Heat the workpiece to 120°C with a gradient of
5°C/min.
After switching on the process, the heater controls the power
output so the heating curve for the workpiece follows the
gradient set.
During heating, a white dotted line is shown in the chart,
indicating the ideal curve for the heating process. The actual
curve will be slightly above this line, since the controller first
has to find a balance between temperature increase and the
matching power output.
NOTE! This mode functions well only if the gradient set is
realistic in relation to the maximum power that the heater can
output and input into the workpiece.
The gradient can be set in X°C/min.
In this mode, one or more temperature sensors have to be
used that are positioned on the workpiece to be heated.

Table of Contents