Regular Cleaning
Bean Hoppers Cleaning
Never reach into the coffee grinders!
Clean the bean hoppers as required and at regular intervals (at least monthly). ►
Switch off the coffee machine with the ON/OFF button. Remove mains plug. ►
► Release bean hopper screw closure by turning it anticlockwise.
Lift bean hoppers out. ►
Completely empty bean hoppers and wipe thoroughly with a damp cloth. ►
Allow bean hoppers to dry completely. ►
Refill and replace bean hoppers. ►
Close the svrew closure by turning it clockwise. ►
Never wash the bean hoppers in a dishwasher.
Product Hopper Cleaning / Choc/Topping (optional) / Twin-Topping (optional)
Depending on powder used cleaning will be more/less frequent!
Switch off the coffee machine with the ON/OFF button. Remove mains plug. ►
► Open the closure of the product hopper by pressing the interlock switch.
Lift product hopper out and empty completely. ►
Unscrew union nut(s) front and rear. ►
Remove the dosing auger(s). ►
Thoroughly clean out reservoir with a damp cloth. ►
Thoroughly clean individual dosing auger(s) components. ►
Allow product hopper and individual components to dry completely. ►
Re-assemble and replace the dosing auger(s) and replace union screws. ►
Refill and replace product hopper. ►
Never clean product hoppers in the dishwasher.
Special features of the twin topping container:
The twin topping container is separated in the middle and has different compartments for two different pow-
der products, e.g. topping and choc.
► Ensure that the two different dosing augers are positioned correctly during assembly (1 = Choc / 2 =
Topping).
Filter Changing
When changing filters follow the anti-scale filter instructions for use.
Execute a rinse after a filter change. The messages on the display are leading through the rinse.
For Filter Change see chapter Software.
Descaling
The messages on the display are leading through the descaling.
For Descaling see chapter Software.
CAUTION!
Risk of squeezing!
CAUTION!
Machine at risk!
CAUTION!
Machine at risk!
Dismantled dosing augers
1
2