EasyManua.ls Logo

Schaerer Coffee Vito - Installing a waste water outlet; Connecting the milk

Schaerer Coffee Vito
86 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
www.schaerer.com Installation and commissioning
BA SCV_EN
V05 | 04.2013
18
Installing a waste water outlet
Option 1: Inserting a drip tray without an opening
Insert the drip tray.
Option 2: Drip tray with opening
Insert the drip tray.
Fit the waste water connection (see below)
Option 3: Waste water connection
Push the hose with the elbow onto the end of the hose on the rear side of the machine.
Connect the discharge hose to the waste water system.
Make sure that the hose does not sag (shorten it if necessary!).
Connecting the milk
Push the beverage outlet to its highest position.
Press the release on the rear side of the beverage outlet and pull the foamer head down-
wards.
Conduct the milk hose through the opening (arrow) and fit it onto the foamer head (see il-
lustration).
From below insert the foamer head upwards again into the beverage outlet guide until it
engages.
Option 1: External cooling units
Conduct the milk hose through the bottom openings (see illustration). If the beverage outlet
is misadjusted, make sure that the milk hose is not kinked.
Select the desired milk nozzle (included in the scope of supply) and insert it at the end of
the hose that is located on the outside.
The milk connection is ready for external milk cooling units.
With the option "Aquaflex" a selection can be made from the above mentioned options.