BA SCV_EN
V05 | 04.2013
77
www.schaerer.comTroubleshooting
88 Boiler temperature too
high
The water supply is interrupted.
Dispensing of beverages is blocked.
Option 1: With drinking water tank
► Check that the drinking water tank is filled
and installed correctly.
Option 2: With mains water supply
► Check whether the main water valve is
open.
The brew unit is blocked.
Dispensing of beverages is blocked.
► Clean the brew unit.
See "Cleaning" - "Weekly cleaning".
The machine is overheated.
Dispensing of beverages is blocked.
► Switch off the coffee machine and let it
cool.
► Switch the coffee machine back on.
► If not rectified, contact your service part-
ner.
89 Boiler heating time
fault
Fault while heating ► Switch the machine off and back on.
161 Brew water fault The water supply is interrupted.
Dispensing of beverages is blocked.
Option 1: With drinking water tank
► Check that the drinking water tank is filled
and installed correctly.
Option 2: With mains water supply
► Check whether the main water valve is
open.
Option 3: Aquaflex
► Check whether the changeover from
mains water supply and drinking water
tank is correctly set.
See "Installation and commissioning" -
"Changeover from mains water supply to
drinking water tank"
The brew unit is blocked.
Dispensing of beverages is blocked.
► Clean the brew unit.
See "Cleaning" - "Weekly cleaning".
The grinding fineness setting is too fine.
The fine dust contaminates the mill too quick-
ly.
► Set the grinding fineness one level coars-
er.
See "Service and maintenance" - "Finer set-
ting of grind level".
The highest quality level can lead to a brew
water fault.
► Set the quality lower.
See "Programming" - "Settings" menu -
"Recipes and beverage buttons".
163 Warm rinse water fault The water supply is interrupted.
Dispensing of beverages is blocked.
Option 1: With drinking water tank
► Check that the drinking water tank is filled
and installed correctly.
Option 2: With mains water supply
► Check whether the main water valve is
open.
The brew unit is blocked.
Dispensing of beverages is blocked.
► Clean the brew unit.
See "Cleaning" - "Weekly cleaning".
186 Steam boiler level The level in the steam boiler has not been
reached within 30 sec.
The steam feed valve is defective.
► Switch the coffee machine off and back
on.
► If not rectified, contact your service part-
ner.
Code Designation Cause and effect What to do