DOOR SUET BOARD DISCONNECTED
A1:Check: SUET connection
0338
DOOR SUET ERROR1 OVERBRIDGING ACTIVATION UNSUCCESSFUL
A1:Check: SUET board
0339
DOOR SUET ERROR2 OVERBRIDGING LOST
The elevator has recognized an unexpected deactivation of the door safety
circuit bypass. Note that this overbridging is activated during re-leveling or
advanced door opening (pre-opening).
C1:Door zone detection faulty
A1:Check door zone signals and sensors (for example, PHSx, PHUETx).
C2:A door safety circuit bypass feedback signal (for example, IUET,
RFUET) is faulty
A2:Check general wiring at door safety circuit bypass device (for
example, SUET)
C3:The car has unintentionally left the door zone while the door safety
circuit was bypassed
A3:Check why the car has left the door zone
C4:Failure at door safety circuit bypass device
A4:Replace corresponding device (for example, SUET)
0340
DOOR SUET ERROR3 OVERBRIDGING DEACTIVATION UNSUCCESSFUL
A1:Check: SUET board
0341
DOOR RPHT SIGNAL BLOCKED ACTIVE
This error message is logged when the RPHT error counter reached its limit
value (for example, PPHT signal got active while the door was closed).
C1:Sticker on the photo cell
A1:Remove sticker
C2:Photo cell defect
A2:Check photo cell, replace it if necessary
0342
DOOR RPHT SIGNAL RECOVERED NORMAL OPERATION
The RPHT signal has recovered, the RPHT signal is inactive in the state door
closed
0343 DOOR SUET ERROR4 OVERBRIDGED WITHOUT ACTIVATION *)
0344
DOOR RPHT SIGNAL BLOCKED INACTIVE
There was a failure of the door safety circuit bypass
Note: This bypass is activated during re leveling or advanced door opening
(pre opening)
0345
DOOR DESTRUCTIVE OVERTEMPERATURE
The door drive (motor) has exceeded its the destructive over-temperature limit
0351
DOOR POSITION RECOVERY SUCCESSFUL
The door was able to recover from a position problem