4.11.3.2 Maintenance Task List
This instruction does not contain national norms, regulations and contractual
stipulations.
Task List
Key of abbreviations: M = month
4.11.3.3 Maintenance Check
This instruction does not contain national norms, regulations and contractual
stipulations.
General Check
Cleaning
Check the Oil Level
Check the Height of
the Buffers
Check the Safety
Switch
4.11.3.4 Replacement
Worn and / or defective safety components must be replaced by original spare parts
only.
Interval
1)
1) These tasks must be completed after a buffer impact.
Description
12 M
General check
1)
12 M Clean
1)
12 M Check the oil level
1)
12 M Check the height of the buffers
1)
12 M Check the safety switch
1)
No Step
1
Check the buffer and its horizontal support (if available) for any damage.
No Step
1
Clean the buffer casing.
2 Clean the plunger and oil lightly.
No Step
1
Check the oil level with the indicator. The minimum (B) and maximum (A) oil
levels allowed are marked on the indicator.
No Step
1
Check the HP dimension when the buffer is fully extended.
No Step
1
Check that the safety switch operates smoothly and works correctly.