EasyManua.ls Logo

Schindler 3300 - Elevator Status (Indication on HMI)

Schindler 3300
269 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Schindler 3100/3300/6300 J 43402603 / 01 86/269
Copyright © 2017 INVENTIO AG
4.9.1.4 Elevator Status (Indication on HMI)
System Status
No System Status No System Status
00
Out of service operation 53 Inspection machine room
01 Passenger travel operation 54 Inspection top of car
02 Independent operation, reservation control 57 Test travel
03 Fire operation 58 Acceptance Test mode
05 Emergency power operation without load
monitoring
59 Learning travel
06 Earthquake operation 60 Inspection preparation travel
08 Sprinkler operation 61 Overspeed governor reset
travel
10 Attended passenger travel operation 65 Inspection in pit
11 Passenger travel operation without load
monitoring
67 TSD21
13 Power saving mode 70 Elevator recovery
16 Hospital emergency travel 71 Elevator temperature recovery
19 Passenger travel full load service 72 Elevator car position recovery
20 In car alarm passenger travel operation
service
73 Elevator door position recovery
29 Move around operation 75 Out of service due to safety
chain open at ISPT
37 Out of service due to stop in car 80 Stop switch
39 Out of service due to car overload 86 Stop switch pressed in the pit
40 Out of service due to invalid configuration
data
87 Out of service due to brake
failure (brake torque monitoring
test failed)
42 Out of service due to invalid LMS
configuration
88 Out of service due to static
safety circuit open
44 Out of service from remote 91 Elevator startup
45 Out of service STM monitoring failure 97 Elevator breakdown persistent
limited operation
51 Installation travel 98 Elevator breakdown
52 Configuration mode 99 Elevator breakdown persistent

Table of Contents