2404
FC MOVE CMD TIMEOUT ERROR
The elevator main controller does not receive the expected data from the drive
node within the expected time after a request.
C1:Different causes
A1:Check elevator message log for previous reported messages in order
to identify the root cause of the problem.
C2:The elevator main controller and the drive are out of sync.
A2:Perform a reset of the entire system
2405
FC DRIVE PHASE
C1:Drive (FC) reports phase inconsistent
A1:Check CAN cable. Check CAN cable termination
C2:The FC phase (state) is not consistent with the previous one. (for
example, if after standstill, decelerating is sent).There has either missing
a message or the FC software has a bug.Has nothing to with electrical
motor phase connections.
2406
FC PROXY WARNING DISTANCE ZERO MOVE RQST
C1:The FC has received a zero distance move request.This is an EC
application (internal) error.
2407
FC PROXY WARNING DIRECTION NONE MOVE RQST
C1:The FC has received a no direction move request.This is an EC
application (internal) error.
2408
FC PROXY WARNING DIRECTION INVERSION MOVE RQST
C1:EC application (internal) error.If within a trip from one move request
to another the direction changes.
2409
FC PROXY WARNING ZERO LEVELS MOVE_RQST
C1:The FC has received a zero level move request.This is an EC
application (internal) error.
2410
FC PROXY WARNING NESTED MOVE RQST
C1:EC application (internal) error. If a move command tries to override
another one.
2411
FC PROXY WARNING MOVE RQST WHILE STOPPING
C1:EC application (internal) error. EC does not stick to the given time-
outs.
2412
FC PROXY WARNING MOVE RQST WHILE UNAVAILABLE
C1:EC application (internal) error. EC does not stick to the given time-
outs.
2413
FC PROXY WARNING MOVE RQST WITH WRONG FC MODE
C1:EC application (internal) error. After startup the enable delay is too
long.
2414
FC PROXY WARNING RQST TO RECOVER AFTER FATAL
C1:EC application (internal) error. EC tried to recover from a fatal error.
2415
FC PROXY WARNING SAFETY CHAIN WILL BE DISABLED
C1:Due to FC error the safety chain will be disabled (via RH1 relay).