Schindler 3100/3300/6300 J 43402603 / 01 152/269
Copyright © 2017 INVENTIO AG
Code EEPROM Message
3501
SAFETY CHAIN PIT CONTACT OVERBRIDGING ACTIVATION
The overbridging of the safety circuit contacts in the pit (for example, used in
fire operation Korea) wasn't successful.
C1:Overbridging relays defect
A1:Check function of relays RUESG, RUESG1 and RSG_A
C2:Wiring from/to overbridging relays bad
A2:Check wiring of relays RUESG, RUESG1 and RSG_A
C3:Fieldbus communication problem (please check previous errors in
error log)
A3:Check error 3603 for cause and actions
3502
SAFETY CHAIN PIT CONTACT OVERBRIDGING LOST
The overbridging of the safety circuit contacts in the pit (for example, used in
fire operation Korea) was lost.
C1:Overbridging relays defect
A1:Check function of relays RUESG, RUESG1 and RSG_A
C2:Wiring from/to overbridging relays bad
A2:Check wiring of relays RUESG, RUESG1 and RSG_A
C3:Fieldbus communication problem (please check previous errors in
error log)
A3:Check error 3603 for cause and actions
3503
SAFETY CHAIN PIT CONTACT OVERBRIDGING DEACTIVATION
The cancellation of the overbridging of the safety circuit contacts in the pit (for
example, used in fire operation Korea) wasn't successful.
C1:Overbridging relays defect
A1:Check function of relays RUESG, RUESG1 and RSG_A
C2:Wiring from/to overbridging relays bad
A2:Check wiring of relays RUESG, RUESG1 and RSG_A
C3:Fieldbus communication problem (please check previous errors in
error log)
A3:Check error 3603 for cause and actions
3504
SAFETY CHAIN PIT CONTACT UNEXPECTED OVERBRIDGING
An unexpected overbridging of the safety circuit contacts in the pit has
occurred.
C1:Overbridging relays defect
A1:Check function of relays RUESG, RUESG1 and RSG_A
C2:Wiring from/to overbridging relays bad
A2:Check wiring of relays RUESG, RUESG1 and RSG_A
C3:Fieldbus communication problem (please check previous errors in
error log)
A3:Check error 3603 for cause and actions