EasyManua.ls Logo

Schindler 3300 - Page 36

Schindler 3300
269 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Schindler 3100/3300/6300 J 43402603 / 01 36/269
Copyright © 2017 INVENTIO AG
Watch Dog The TA device limits a call for max. 3 minutes. Afterwards the connection will be
interrupted.
The command below restarts the timer for next 3 minutes w/o interruption of the
communication.
It can be used with each connection independent of alarm- back- or configuration call.
2)
If the alarm device answers with #99# then the TA device did not get the DTMF
commands right. Try again to send the command.
Automatic Periodical
Call Procedure
2)
If the alarm device answers with #99# then the TA device did not get the DTMF
commands right. Try again to send the command.
Rescue Service Handling from to Remote Alarm Device
Watch Dog
- start the watch
dog with
#23# - The TA device starts
the timer for next 3
minutes
#00#
2)
- sends ok
Rescue Service Handling from to Remote Alarm Device
Establish
Connectio
n
ring - The TA device dials
the rescue alarm
number
- the rescue service
answers the incoming
call
Verify
Installation
ID
- ask the Installation ID
with
#10#
#12xxxxxxxxxxxx#
- sends Installation ID
(x=0 ... 999999999999)
Verify Unit
ID
- ask the Unit ID with #13#
#14abcd# - sends Unit ID
(a=1 ... 8)
(b=1: test call)
Set Line
Test Timer
- Set line test timer
(x=0 ... 99999 minutes)
#74xxxxx# - sets line test timer
#00#
2)
- sends ok
Close
Connectio
n
- send the hang up
signal
#24#
- the rescue service
hangs up
#00#
2)
- sends ok
TA device hangs up the
phone line

Table of Contents

Related product manuals