Schindler 3100/3300/6300 J 43402603 / 01 38/269
Copyright © 2017 INVENTIO AG
In case of ETMA Wireless device, below information is to the third party to reconfigure
the ETMA Wireless device.
With simple SMS, the third party is able to reconfigure
– Installation ID
– Alarm numbers
– Line test number and Line test timer
– SMS numbers for notifications.
Configuration
Installation ID and
Alarm Numbers
– Send an SMS to the mobile phone number of the ETMA WL GSM with the content
described below
– The ETMA WL GSM will send back a confirmation about the success of the
configuration.
SMS Configuration
Content for Alarm
All headers and all line endings must be present in the SMS. If there are only one or two
alarm number, reuse the same phone number for the others or leave it empty.
OEM-Config SMS of String Declaration as a Configuration for Third Party
SERNO Header of the serial number
2345678901 Serial number of the target ETMA-MR-GSM
INSTID Header of Installation ID
123456789012 Installation ID (maximum 12 characters long)
ANUM1 Header of the first alarm number
+4141123456 First alarm number
ANUM2 Header of the second alarm number
+4141123457 Second alarm number
ANUM3 Header of the third alarm number
+4141123458 Third alarm number
ANUM4 Header of the fourth alarm number
+4141123459 Fourth alarm number
LNUM Header of the Line test number
+4141123459 Line test number
LTT Header of the Line test timer
4320 Line test timer in minutes (3 days = 4320 min)
# Declares the end of the SMS