Schindler 3100/3300/6300 J 43402603 / 01 94/269
Copyright © 2017 INVENTIO AG
Normal Reset - Car Top
Using Inspection
Panel Top of Car
(REC)
Normal Reset – in Pit
Using Inspection
Panel in Pit (RESG)
[604639_018; 26.07.2017]
It is possible to reset the control with help of the
inspection panel on top of car:
JREC must be on position “INSPECTION”
JHC stop button must be pressed
Press the ENABLE, UP and DOWN buttons
(DREC-E, DREC-U and DREC-D)
simultaneously.
This will reset the elevator control.
NORMAL
REC
DREC-U
HC
DREC-D
DA-U
PC
ENABLE
I
N
S
P
E
C
T
I
O
N
STOP
[604639_019; 26.07.2017]
It is possible to reset the control with help
of the inspection panel in pit:
JREC must be on position
“INSPECTION”
JHC stop button must be pressed
Press the ENABLE, UP and DOWN
buttons (DRESG-E, DRESG-U and
DRESG-D) simultaneously.
This will reset the elevator control.