Mount new sensor assembly
Ø Carefully screw the new sensor(6) or(7) into SWK(4) until the
sensor(6) or(7) touches the detection shaft.
Ø Unscrew sensor(6) or(7) by half a turn.
Ø Hold sensor(6) or(7) in this position and connect sensor cable.
The sensor LED will illuminate.
Ø Apply screw lock to screw(3) and fasten sensor(6) or(7) with
screw(3).
WARNINGRisk of damage to the sensor! Carefully tighten
screw(3) until screw(3) engages in the sensor thread, then
tighten another 1/4 turn.
Check new sensor assembly
Ø Connect all compressed air lines.
Ø Secure the adapter plate(2) to SWK(4) with screws(5).
Max. tightening torque: 1.13Nm
Ø Guide the sensor cable along the cable ducts in the adapter
plate(2) and secure it with screws(1).
Max. tightening torque: 0.9Nm
Ø Lock and unlock the locking piston and check the signals of the
sensors.